USING THE LIGHT TOWER
AUTOMATIC ENGINE SHUTDOWN SYSTEMS
The engine is equipped with several automatic engine
shutdown systems. These systems are in place to
prevent excessive engine damage in the event of a low
oil or overheat condition. For additional information,
refer to your Engine Operator’s Manual.
LOW OIL PRESSURE SHUTOFF
If a low oil pressure condition occurs, the oil pressure
sending unit breaks the circuit between the battery and
the fuel solenoid, which shuts off the fuel.
HIGH COOLANT TEMPERATURE SHUTOFF
If a high coolant temperature condition occurs, the
temperature sending unit breaks the circuit between
the battery and the fuel solenoid, which shuts off the
fuel.
FUELING YOUR LIGHT TOWER
Open either side panel. The fuel tank is actually two
tanks, one on each side, both with filler caps. The tanks
are connected, so filling either side will fill the entire
tank. The trailer holds 100 gallons (378.5 L).
Good quality #1 or #2 Diesel fuel are both acceptable
Do not use an alternative fuel because its quality is
unknown and may be inferior. Kerosene, which has a
very low octane rating, adversely affects the engine.
Refer to the Engine Operator’s Manual for more detailed
fuel requirements.
NOTICE
Pressurized fueling is NOT ALLOWED.