ROUTINE MAINTENANCE SCHEDULE
KUBOTA D905 and D1105 and PERKINS 103-10
INSPECTION AND LUBRICATION SCHEDULE
Check hydraulic fluid level.
Lubrication grease specifications: N.G.L.I. consistency #2, high temperature anti-friction
bearing lubricating grease.
Service intervals shown below have been established for operation under normal conditions.
Where equipment is operated under severe conditions (very dusty, extreme heat or cold, etc.)
affected items should be serviced more frequently.
INTERVAL ITEM PROCEDURE
Fuel level Check and fill as necessary
Lubricating oil Check level and condition
Daily or 10 Hr.
Air Cleaner
Clean under very dusty
conditions.
All 10 Hr. items As above
Air Cleaner
Service as required. Service
requirements may be accelerated
Battery Check level of electrolyte
100 Hr.
Engine Generator assembly
Check for fuel and lubricating oil
leaks
All 100 Hr. items As above
Engine lubricating oil system
Drain lubricating oil, flush out
system, renew filter element and
refill with correct grade and type
oil
200 Hr.
Coolant Check level and condition
400 Hr. Fuel Filter Replace with new.
All 200 Hr. Items As above
Fan belt Check tension and condition500 Hr.
Radiator Clean out fins with water or air
All 500 Hr. Items As above
Engine Valves Adjust clearance
Axle wheel bearings Clean and repack
Fuel System Clean sediment from tank
1000 hr. or yearly
1000 hr. or yearly